{"title":"Fire Alarm (Riser)","description":null,"products":[{"product_id":"ver-216-142-r-rd-14-2-fplr-fire-alarm-wire-1000ft","title":"#14\/2 Fire Alarm Jacketed Riser FPLR - 1000ft Reel - Red","description":"\u003cdiv id=\"click_to_dial_wrapper\" style=\"text-align: center;\"\u003eFor project pricing and freight quotes on large wire \u0026amp; cable orders please call us now!??\u003ca title=\"Click to dial with Communicator\" href=\"glocom:\/\/18558185556\"\u003e1-855-818-5556\u003c\/a\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eThis product may be available in one of our regional warehouses. Call us for best shipping option!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 216-142\/R\/RD is a 14 gauge 2 conductor FPLR solid fire alarm wire used for power limited fire alarm and communications applications. It is perfect for wiring fire alarm systems, smoke detectors, and various fire protective circuits. The 14-2 fire alarm wire is designed to support both riser and non-riser fire alarm wiring applications.\u003c\/p\u003e\n\u003cp\u003eThis 14-2 fire alarm wire is sun resistance, includes a ripcord and sequential footage markings, and has color coded conductors for easy identification. It is constructed using 14 gauge solid bare copper conductors and supports 300v operations. 14-2 FPLR fire alarm wire is common for use in both residential and commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eOur 14-2 FPLR fire alarm wire is manufactured to Type FPLR, NEC Article 760, and California State Fire Marshal standards. Type FPLR power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft or from floor to floor. All FPLR cables are listed as having fire-resistant characteristics capable of preventing fire from traveling floor to floor. This 14-2 fire alarm wire is tested to pass both UL test 1424 and the vertical riser flame test UL 1666.\u003c\/p\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":51042182889793,"sku":"VER-216-142\/R\/RD","price":387.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/315-142_R_RD.jpg?v=1764303237"},{"product_id":"ver-216-142-s-r-rd-14-2-shielded-fplr-fire-alarm-wire-1000ft","title":"#14\/2 Fire Alarm Jacketed Riser Shielded FPLR - 1000ft Reel - Red","description":"\u003cdiv id=\"click_to_dial_wrapper\"\u003eFor project pricing and freight quotes on large wire \u0026amp; cable orders please call us now!??\u003ca title=\"Click to dial with Communicator\" href=\"glocom:\/\/18558185556\"\u003e1-855-818-5556\u003c\/a\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eThis product may be available in one of our regional warehouses. Call us for best shipping option!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 216-142\/S\/R\/RD is a 14 gauge 2 conductor shielded FPLR solid fire alarm wire used for power limited fire alarm and communications applications. It is perfect for wiring fire alarm systems, smoke detectors, and various fire protective circuits. The 14-2 fire alarm wire is designed to support both riser and non-riser fire alarm wiring applications where overall shielding is required. The overall shielding on this 14-2 fire alarm wire will protect your signals from any outside interference that could interrupt the integrity of your fire alarm system. ?\u003c\/p\u003e\n\u003cp\u003eThis 14-2 fire alarm wire is sun resistance, includes a ripcord, drain wire, sequential footage markings, and an overall foil shield. It also has color coded conductors for easy identification. This 14-2 shielded fire alarm wire is constructed using 14 gauge solid bare copper conductors and supports 300v operations. 14-2 FPLR fire alarm wire is common for use in both residential and commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eOur 14-2 FPLR fire alarm wire is manufactured to Type FPLR, NEC Article 760, and California State Fire Marshal standards. Type FPLR power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft or from floor to floor. All FPLR cables are listed as having fire-resistant characteristics capable of preventing fire from traveling floor to floor. This 14-2 fire alarm wire is tested to pass both UL test 1624 and the vertical riser flame test UL 1666.\u003c\/p\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":51042182922561,"sku":"VER-216-142\/S\/R\/RD","price":328.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/315-142_S_P_RD_282e8f82-3276-4ce7-a5d8-0c0d4d5d6da6.jpg?v=1764303240"},{"product_id":"ver-216-162-r-rd-16-2-fplr-fire-alarm-wire-1000ft","title":"#16\/2 Fire Alarm Jacketed Riser FPLR - 1000ft Reel - Red","description":"\u003cdiv id=\"click_to_dial_wrapper\" style=\"text-align: center;\"\u003eFor project pricing and freight quotes on large wire \u0026amp; cable orders please call us now!??\u003ca title=\"Click to dial with Communicator\" href=\"glocom:\/\/18558185556\"\u003e1-855-818-5556\u003c\/a\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eThis product may be available in one of our regional warehouses. Call us for best shipping option!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 16\/2FPLR is a 16 gauge 2 conductor FPLR solid fire alarm wire used for power limited fire alarm and communications applications. It is perfect for wiring fire alarm systems, smoke detectors, and various fire protective circuits. The 16-2 fire alarm wire is designed to support both riser and non-riser fire alarm wiring applications.\u003c\/p\u003e\n\u003cp\u003eThis 16-2 fire alarm wire is sun resistance, includes a ripcord and sequential footage markings, and has color coded conductors for easy identification. It is constructed using 16 gauge solid bare copper conductors and supports 300v operations. 16-2 FPLR fire alarm wire is common for use in both residential and commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eOur 16-2 FPLR fire alarm wire is manufactured to Type FPLR, NEC Article 760, and California State Fire Marshal standards. Type FPLR power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft or from floor to floor. All FPLR cables are listed as having fire-resistant characteristics capable of preventing fire from traveling floor to floor. This 16-2 fire alarm wire is tested to pass both UL test 1424 and the vertical riser flame test UL 1666.\u003c\/p\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":51042182988097,"sku":"VER-216-162\/R\/RD","price":243.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/315-142_R_RD_60f9ac17-81a5-41ff-8cf6-06171b1b14a9.jpg?v=1764303248"},{"product_id":"ver-216-162-s-r-rd-16-2-shielded-fplr-fire-alarm-wire-1000ft","title":"#16\/2 Fire Alarm Jacketed Riser Shielded FPLR - 1000ft Reel - Red","description":"\u003cdiv id=\"click_to_dial_wrapper\" style=\"text-align: center;\"\u003eFor project pricing and freight quotes on large wire \u0026amp; cable orders please call us now!??\u003ca title=\"Click to dial with Communicator\" href=\"glocom:\/\/18558185556\"\u003e1-855-818-5556\u003c\/a\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eThis product may be available in one of our regional warehouses. Call us for best shipping option!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 16\/2FPLR is a 16 gauge 2 conductor shielded FPLR solid fire alarm wire used for power limited fire alarm and communications applications. It is perfect for wiring fire alarm systems, smoke detectors, and various fire protective circuits. The 16-2 fire alarm wire is designed to support both riser and non-riser fire alarm wiring applications where overall shielding is required. The overall shielding on this 16-2 fire alarm wire will protect your signals from any outside interference that could interrupt the integrity of your fire alarm system. ?\u003c\/p\u003e\n\u003cp\u003eThis 16-4 fire alarm wire is sun resistance, includes a ripcord, drain wire, sequential footage markings, and an overall foil shield. It also has color coded conductors for easy identification. This 16-4 shielded fire alarm wire is constructed using 16 gauge solid bare copper conductors and supports 300v operations. 16-2 FPLR fire alarm wire is common for use in both residential and commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eOur 16-2 FPLR fire alarm wire is manufactured to Type FPLR, NEC Article 760, and California State Fire Marshal standards. Type FPLR power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft or from floor to floor. All FPLR cables are listed as having fire-resistant characteristics capable of preventing fire from traveling floor to floor. This 16-2 fire alarm wire is tested to pass both UL test 1424 and the vertical riser flame test UL 1666.\u003c\/p\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":51042183151937,"sku":"VER-216-162\/S\/R\/RD","price":261.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/315-142_S_P_RD_cc4711b7-49b6-4675-914e-f4c0b3482c3e.jpg?v=1764303251"},{"product_id":"ver-216-182-r-rd-18-2-fplr-fire-alarm-wire-1000ft","title":"#18\/2 Fire Alarm Jacketed Riser FPLR - 1000ft Reel - Red","description":"\u003cdiv id=\"click_to_dial_wrapper\" style=\"text-align: center;\"\u003eFor project pricing and freight quotes on large wire \u0026amp; cable orders please call us now!??\u003ca title=\"Click to dial with Communicator\" href=\"glocom:\/\/18558185556\"\u003e1-855-818-5556\u003c\/a\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eThis product may be available in one of our regional warehouses. Call us for best shipping option!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 18\/2FPLR is an 18 gauge 2 conductor FPLR solid fire alarm wire used for power limited fire alarm and communications applications. It is perfect for wiring fire alarm systems, smoke detectors, and various fire protective circuits. The 18-2 fire alarm wire is designed to support both riser and non-riser fire alarm wiring applications.\u003c\/p\u003e\n\u003cp\u003eThis 18-2 fire alarm wire is sun resistance, includes a ripcord and sequential footage markings, and has color coded conductors for easy identification. It is constructed using 18 gauge solid bare copper conductors and supports 300v operations. 18-2 FPLR fire alarm wire is common for use in both residential and commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eOur 18-2 FPLR fire alarm wire is manufactured to Type FPLR, NEC Article 760, and California State Fire Marshal standards. Type FPLR power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft or from floor to floor. All FPLR cables are listed as having fire-resistant characteristics capable of preventing fire from traveling floor to floor. This 18-2 fire alarm wire is tested to pass both UL test 1424 and the vertical riser flame test UL 1666.\u003c\/p\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":51042183184705,"sku":"VER-216-182\/R\/RD","price":166.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/315-142_R_RD_1b2d6bf6-f2ec-42f5-bade-842065ce58c0.jpg?v=1764303255"},{"product_id":"ver-216-182-s-r-rd-18-2-shielded-fplr-fire-alarm-wire-1000ft","title":"#18\/2 Fire Alarm Jacketed Riser Shielded FPLR - 1000ft Reel - Red","description":"\u003cdiv id=\"click_to_dial_wrapper\" style=\"text-align: center;\"\u003eFor project pricing and freight quotes on large wire \u0026amp; cable orders please call us now!??\u003ca title=\"Click to dial with Communicator\" href=\"glocom:\/\/18558185556\"\u003e1-855-818-5556\u003c\/a\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eThis product may be available in one of our regional warehouses. Call us for best shipping option!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 18\/2FPLR is an 18 gauge 2 conductor shielded FPLR solid fire alarm wire used for power limited fire alarm and communications applications. It is perfect for wiring fire alarm systems, smoke detectors, and various fire protective circuits. The 18-2 fire alarm wire is designed to support both riser and non-riser fire alarm wiring applications where overall shielding is required. The overall shielding on this 18-2 fire alarm wire will protect your signals from any outside interference that could interrupt the integrity of your fire alarm system. ?\u003c\/p\u003e\n\u003cp\u003eThis 18-4 fire alarm wire is sun resistance, includes a ripcord, drain wire, sequential footage markings, and an overall foil shield. It also has color coded conductors for easy identification. This 18-4 shielded fire alarm wire is constructed using 18 gauge solid bare copper conductors and supports 300v operations. 18-2 FPLR fire alarm wire is common for use in both residential and commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eOur 18-2 FPLR fire alarm wire is manufactured to Type FPLR, NEC Article 760, and California State Fire Marshal standards. Type FPLR power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft or from floor to floor. All FPLR cables are listed as having fire-resistant characteristics capable of preventing fire from traveling floor to floor. This 18-2 fire alarm wire is tested to pass both UL test 1424 and the vertical riser flame test UL 1666.\u003c\/p\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":51042183250241,"sku":"VER-216-182\/S\/R\/RD","price":169.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/315-142_S_P_RD_408a171a-d062-4785-b943-f973fb421a94.jpg?v=1764303262"},{"product_id":"ver-216-184-r-rd-fplr-18-4-fire-alarm-wire","title":"#18\/4Fire Alarm Jacketed Riser FPLR - 1000ft Reel - Red","description":"\u003cp\u003eThe 18\/4FPLR is an 18 gauge 4 conductor FPLR solid fire alarm wire used for power limited fire alarm and communications applications. It is perfect for wiring fire alarm systems, smoke detectors, and various fire protective circuits. The 18-4 fire alarm wire is designed to support both riser and non-riser fire alarm wiring applications.\u003c\/p\u003e\n\u003cp\u003eThis 18-4 fire alarm wire is sun resistance, includes a ripcord and sequential footage markings, and has color coded conductors for easy identification. It is constructed using 18 gauge solid bare copper conductors and supports 300v operations. 18-4 FPLR fire alarm wire is common for use in both residential and commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eOur 18-4 FPLR fire alarm wire is manufactured to Type FPLR, NEC Article 760, and California State Fire Marshal standards. Type FPLR power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft or from floor to floor. All FPLR cables are listed as having fire-resistant characteristics capable of preventing fire from traveling floor to floor. This 18-4 fire alarm wire is tested to pass both UL test 1424 and the vertical riser flame test UL 1666.\u003c\/p\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":51042187084097,"sku":"VER-216-184\/R\/RD","price":297.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/315-144_R_RD_d3c692c4-44a0-4e8f-a664-396511d6d53e.jpg?v=1764303312"},{"product_id":"12-2-fplr-solid-fire-alarm-wire-1000ft","title":"#12\/2 Fire Alarm Jacketed Riser FPLR - 1000ft Reel - Red","description":"\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eFor project pricing and freight quotes on large wire \u0026amp; cable orders please call us now!? 1-855-818-5556\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eThis product may be available in one of our regional warehouses. Call us for best shipping option!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 12\/2FPLR is a 12 gauge 2 conductor FPLR solid fire alarm wire used for power limited fire alarm and communications applications. It is perfect for wiring fire alarm systems, smoke detectors, and various fire protective circuits. The 12-2 fire alarm wire is designed to support both riser and non-riser fire alarm wiring applications.\u003c\/p\u003e\n\u003cp\u003eThis 12-2 fire alarm wire is sun resistance, includes a ripcord and sequential footage markings, and has color coded conductors for easy identification. It is constructed using 14 gauge solid bare copper conductors and supports 300v operations. 12-2 FPLR fire alarm wire is common for use in both residential and commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eOur 12-2 FPLR fire alarm wire is manufactured to Type FPLR, NEC Article 760, and California State Fire Marshal standards. Type FPLR power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft or from floor to floor. All FPLR cables are listed as having fire-resistant characteristics capable of preventing fire from traveling floor to floor. This 12-2 fire alarm wire is tested to pass both UL test 1424 and the vertical riser flame test UL 1666.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Structured Cable Products Inc. (SimpleBrands)","offers":[{"title":"Default Title","offer_id":51042187673921,"sku":"SCP-12\/2FPLR","price":707.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/12-2FPLR.jpg?v=1764303366"},{"product_id":"16-4-shielded-fplr-fire-alarm-wire-1000ft","title":"#18\/4 Fire Alarm Jacketed Riser Shielded FPLR - 1000ft Reel - Red","description":"\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eFor project pricing and freight quotes on large wire \u0026amp; cable orders please call us now!  1-855-818-5556 \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eThis product may be available in one of our regional warehouses.   Call us for best shipping option! \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 16\/4FPLR is a 16 gauge 4 conductor shielded FPLR solid fire alarm wire used for power limited fire alarm and communications applications.  It is perfect for wiring fire alarm systems, smoke detectors, and various fire protective circuits. The 16-4 fire alarm wire is designed to support both riser and non-riser fire alarm wiring applications where overall shielding is required.  The overall shielding on this 16-4 fire alarm wire will protect your signals from any outside interference that could interrupt the integrity of your fire alarm system.    \u003c\/p\u003e\n\u003cp\u003eThis 16-4 fire alarm wire is sun resistance, includes a ripcord, drain wire, sequential footage markings, and an overall foil shield. It also has color coded conductors for easy identification.  This 16-4 shielded fire alarm wire is constructed using 16 gauge solid bare copper conductors and supports 300v operations.  16-4 FPLR fire alarm wire is common for use in both residential and commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eOur 16-4 FPLR fire alarm wire is manufactured to Type FPLR, NEC Article 760, and California State Fire Marshal standards. Type FPLR power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft or from floor to floor. All FPLR cables are listed as having fire-resistant characteristics capable of preventing fire from traveling floor to floor. This 16-4 \u003c\/p\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":51042188689729,"sku":"VER-216-184\/S\/R\/RD","price":266.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/16-4FPLR-SH.jpg?v=1764303435"},{"product_id":"22-4-fplr-solid-fire-alarm-wire-1000ft","title":"#22\/4 Fire Alarm Jacketed FPLR - 1000ft - Red","description":"\u003cp\u003eThe 22\/4FPLR is a 22 gauge 4 conductor FPLR solid fire alarm wire used for power limited fire alarm and communications applications. It is perfect for wiring fire alarm systems, smoke detectors, and various fire protective circuits. The 22-4 fire alarm wire is designed to support both riser and non-riser fire alarm wiring applications.\u003c\/p\u003e\n\u003cp\u003eThis 22-4 fire alarm wire is sun resistance, includes a ripcord and sequential footage markings, and has color coded conductors for easy identification. It is constructed using 22 gauge solid bare copper conductors and supports 300v operations. 22-4 FPLR fire alarm wire is common for use in both residential and commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eOur 22-4 FPLR fire alarm wire is manufactured to Type FPLR, NEC Article 760, and California State Fire Marshal standards. Type FPLR power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft or from floor to floor. All FPLR cables are listed as having fire-resistant characteristics capable of preventing fire from traveling floor to floor. This 22-4 fire alarm wire is tested to pass both UL test 1424 and the vertical riser flame test UL 1666.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Structured Cable Products Inc. (SimpleBrands)","offers":[{"title":"Default Title","offer_id":51042191475009,"sku":"SCP-22\/4FPLR","price":164.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/22-4FPLR.jpg?v=1764303604"},{"product_id":"14-4-fire-alarm-jacketed-fplr-br-m-ft-reel-red","title":"#14\/4 Fire Alarm Jacketed Riser FPLR - 1000ft Reel - Red","description":"\u003cp\u003eThe \u003cstrong\u003e14\/4 FPLR Fire Alarm Cable\u003c\/strong\u003e is a 4-conductor, 14 AWG riser-rated cable designed for power-limited fire alarm and fire protective signaling systems. Made with \u003cstrong\u003e100% solid bare copper conductors\u003c\/strong\u003e, it provides dependable performance for fire alarm and security installations.\u003c\/p\u003e\n\u003cp\u003eIdeal for \u003cstrong\u003esmoke alarms and detectors, pull boxes, burglar alarms, and addressable fire alarm systems\u003c\/strong\u003e, this FPLR cable is designed for riser applications. It is \u003cstrong\u003eETL Listed and RoHS Compliant\u003c\/strong\u003e and comes on a \u003cstrong\u003e1,000 ft spool\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e14 AWG \/ 4 Conductor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFPLR Riser-Rated Fire Alarm Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e100% Solid Bare Copper Conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFire Protective Signal Circuit Applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for Smoke Alarms and Detectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for Pull Boxes and Burglar Alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAddressable Fire Alarm System Applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eETL Listed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1,000 ft Spool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":52085972500801,"sku":"VER-216-144\/R\/RD","price":666.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/Capturadepantalla2026-08-17130548.png?v=1786993605"},{"product_id":"16-4-fire-alarm-jacketed-fplr-br-m-ft-reel-red","title":"#16\/4 Fire Alarm Jacketed Riser FPLR - 1000ft Reel - Red","description":"\u003cp\u003eThe \u003cstrong\u003e16\/4 FPLR Fire Alarm Cable\u003c\/strong\u003e is a 4-conductor, 16 AWG riser-rated cable designed for power-limited fire alarm and fire protective signaling circuits. Made with \u003cstrong\u003esolid bare copper conductors\u003c\/strong\u003e, it provides reliable connectivity for fire alarm and security system installations.\u003c\/p\u003e\n\u003cp\u003eIdeal for \u003cstrong\u003esmoke alarms and detectors, pull boxes, burglar alarms, and addressable fire alarm systems\u003c\/strong\u003e, this cable is \u003cstrong\u003eETL Listed and RoHS Compliant\u003c\/strong\u003e and comes on a \u003cstrong\u003e1,000 ft spool\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e16 AWG \/ 4 Conductor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFPLR Riser-Rated Fire Alarm Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSolid Bare Copper Conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFire Protective Signal Circuit Applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eETL Listed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1,000 ft Spool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":52085975843137,"sku":"VER-216-164\/R\/RD","price":408.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/Capturadepantalla2026-08-17130548.png?v=1786993605"},{"product_id":"16-4-fire-alarm-jacketed-shielded-fplr-br-m-ft-reel-red","title":"#16\/4 Fire Alarm Jacketed Riser Shielded FPLR - 1000ft Reel - Red","description":"\u003cp\u003eThe \u003cstrong\u003e16\/4 Shielded FPLR Fire Alarm Cable\u003c\/strong\u003e is a 4-conductor, 16 AWG riser-rated cable designed for power-limited fire alarm and fire protective signaling circuits. Made with \u003cstrong\u003esolid bare copper conductors\u003c\/strong\u003e, it features shielding to help protect signals against \u003cstrong\u003eEMI\/RFI interference\u003c\/strong\u003e for reliable system performance.\u003c\/p\u003e\n\u003cp\u003eIdeal for \u003cstrong\u003esmoke alarms and detectors, pull boxes, burglar alarms, and addressable fire alarm systems\u003c\/strong\u003e, this cable is \u003cstrong\u003eETL Listed and RoHS Compliant\u003c\/strong\u003e and comes on a \u003cstrong\u003e1,000 ft spool\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e16 AWG \/ 4 Conductor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFPLR Riser-Rated Fire Alarm Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielded for EMI\/RFI Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSolid Bare Copper Conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFire Protective Signal Circuit Applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eETL Listed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1,000 ft Spool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":52085976203585,"sku":"VER-216-164\/S\/R\/RD","price":428.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/Capturadepantalla2026-08-17130548.png?v=1786993605"}],"url":"https:\/\/cablingplus.com\/collections\/fire-alarm-plenum-copy.oembed","provider":"CablingPlus","version":"1.0","type":"link"}