{"title":"Fire Alarm (Plenum)","description":null,"products":[{"product_id":"ver-216-182-s-p-rd18-2-fplp-ed-plenum-fire-alarm-wire-1000ft","title":"#18\/2 Fire Alarm Jacketed, Plenum Shielded FPLP - 1000ft Reel - Red","description":"\u003cdiv id=\"click_to_dial_wrapper\" style=\"text-align: center;\"\u003eFor project pricing and freight quotes on large wire \u0026amp; cable orders please call us now!??\u003ca title=\"Click to dial with Communicator\" href=\"glocom:\/\/18558185556\"\u003e1-855-818-5556\u003c\/a\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eThis product may be available in one of our regional warehouses. Call us for best shipping option!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 18\/2FPLP is a shielded plenum rated 18 gauge 2 conductor FPLP solid fire alarm wire used for power limited fire alarm and communications applications. It is perfect for wiring fire alarm systems, smoke detectors, and various fire protective circuits in plenum open-air ventilation environments. The plenum rated jacket on the 18-2 fire alarm wire is designed to support building codes that require plenum cabling.It also includes an overall shielding that will protect your signals from any outside interference that could interrupt the integrity of your fire alarm system.\u003c\/p\u003e\n\u003cp\u003eThis 18-2 fire alarm wire includes a ripcord, drain wire, plenum jacket, sequential footage markings, and an overall foil shield.It is constructed using 18 gauge solid bare copper conductors and supports 300v operations. 18-2 Shielded FPLP fire alarm wire is common for commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eOur 18-2 FPLP fire alarm wire is manufactured to Type FPLP, NEC Article 760, CUL Type CMP\/FT6, and California State Fire Marshal standards. Type FPLP power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft, from floor to floor, or in a plenum open-air circulation ceiling environments.\u003c\/p\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":51042182725953,"sku":"VER-216-182\/S\/P\/RD","price":166.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/315-142_S_P_RD.jpg?v=1764303226"},{"product_id":"ver-216-142-s-p-rd-14-2-shielded-plenum-fire-alarm-wire-1000ft","title":"#14\/2 Fire Alarm Jacketed, Plenum Shielded FPLP - 1000ft Reel - Red","description":"\u003cp\u003eThe 216-142\/S\/P\/RD is a shielded plenum rated 14 gauge 2 conductor FPLP solid fire alarm wire used for power limited fire alarm and communications applications.  It is perfect for wiring fire alarm systems, smoke detectors, and various fire protective circuits in plenum open-air ventilation environments.  The plenum rated jacket on the 14-2 fire alarm wire is designed to support building codes that require plenum cabling.  It also includes an overall shielding that will protect your signals from any outside interference that could interrupt the integrity of your fire alarm system.   \u003c\/p\u003e\n\u003cp\u003eThis 14-2 fire alarm wire includes a ripcord, drain wire, plenum jacket, sequential footage markings, and an overall foil shield.  It is constructed using 14 gauge solid bare copper conductors and supports 300v operations.  14-2 Shielded FPLP fire alarm wire is common for commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eOur 1216-142\/S\/P\/RD fire alarm wire is manufactured to Type FPLP, NEC Article 760, CUL Type CMP\/FT6, and California State Fire Marshal standards. Type FPLP power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft, from floor to floor, or in a plenum open-air circulation ceiling environments. \u003c\/p\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":51042182955329,"sku":"VER-216-142\/S\/P\/RD","price":351.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/315-142_S_P_RD_278a4516-02fc-4dbc-82aa-fa5c33ae69b1.jpg?v=1764303244"},{"product_id":"ver-216-184-s-p-rd-18-4-shielded-plenum-fire-alarm-wire-1000ft","title":"#18\/4 Fire Alarm Jacketed, Plenum Shielded FPLP - 1000ft Reel - Red","description":"\u003cp\u003eThe 18\/4FPLP is a shielded plenum rated 18 gauge 4 conductor FPLP solid fire alarm wire used for power limited fire alarm and communications applications.  It is perfect for wiring fire alarm systems, smoke detectors, and various fire protective circuits in plenum open-air ventilation environments.  The plenum rated jacket on the 18-4 fire alarm wire is designed to support building codes that require plenum cabling.  It also includes an overall shielding that will protect your signals from any outside interference that could interrupt the integrity of your fire alarm system.   \u003c\/p\u003e\n\u003cp\u003eThis 18-4 fire alarm wire includes a ripcord, drain wire, plenum jacket, sequential footage markings, and an overall foil shield.  It is constructed using 18 gauge solid bare copper conductors and supports 300v operations.  18-4 Shielded FPLP fire alarm wire is common for commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eOur 18-4 FPLP fire alarm wire is manufactured to Type FPLP, NEC Article 760, CUL Type CMP\/FT6, and California State Fire Marshal standards. Type FPLP power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft, from floor to floor, or in a plenum open-air circulation ceiling environments. \u003c\/p\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":51042183283009,"sku":"VER-216-184\/S\/P\/RD","price":345.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/315-164_S_R_RD.jpg?v=1764303266"},{"product_id":"ver-216-162-s-p-rd-fplp-shielded-plenum-fire-alarm-wire-1000ft","title":"#16\/2 Fire Alarm Jacketed, Plenum Shielded FPLP - 1000ft Reel - Red","description":"\u003cp\u003eThe 16\/2FPLP is a shielded plenum rated 16 gauge 2 conductor FPLP solid fire alarm wire used for power limited fire alarm and communications applications.  It is perfect for wiring fire alarm systems, smoke detectors, and various fire protective circuits in plenum open-air ventilation environments.  The plenum rated jacket on the 16-2 fire alarm wire is designed to support building codes that require plenum cabling.  It also includes an overall shielding that will protect your signals from any outside interference that could interrupt the integrity of your fire alarm system.   \u003c\/p\u003e\n\u003cp\u003eThis 16-2 fire alarm wire includes a ripcord, drain wire, plenum jacket, sequential footage markings, and an overall foil shield.  It is constructed using 16 gauge solid bare copper conductors and supports 300v operations.  16-2 Shielded FPLP fire alarm wire is common for commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eOur 16-2 FPLP fire alarm wire is manufactured to Type FPLP, NEC Article 760, CUL Type CMP\/FT6, and California State Fire Marshal standards. Type FPLP power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft, from floor to floor, or in a plenum open-air circulation ceiling environments.  \u003c\/p\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":51042187116865,"sku":"VER-216-162\/S\/P\/RD","price":285.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/315-142_S_P_RD_91a1b109-8082-4ee1-a9f6-e6bfcf09e030.jpg?v=1764303316"},{"product_id":"n-a-3","title":"#16\/2 Fire Alarm Jacketed, Plenum FPLP - 1000ft Reel - Red","description":"\u003cp\u003eThe 16\/2FPLP is a plenum rated 16 gauge 2 conductor FPLP solid fire alarm wire used for power limited fire alarm and communications applications.  It is perfect for wiring fire alarm systems, smoke detectors, and various fire protective circuits in plenum open-air ventilation environments.  The plenum rated jacket on the 16-2 fire alarm wire is designed to support building codes that require plenum cabling.   \u003c\/p\u003e\n\u003cp\u003eThis 16-2 fire alarm wire is sun resistance, includes a ripcord and sequential footage markings, and has color coded conductors for easy identification.  It is constructed using 16 gauge solid bare copper conductors and supports 300v operations.  16-2 FPLP fire alarm wire is common for commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eOur 16-2 FPLP fire alarm wire is manufactured to Type FPLP, NEC Article 760, CUL Type CMP\/FT6, and California State Fire Marshal standards. Type FPLP power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft, from floor to floor, or in a plenum open-air circulation ceiling environments.  \u003c\/p\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":51158881632577,"sku":"VER-216-162\/P\/RD","price":270.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/Capturadepantalla2026-04-07153244.png?v=1775597586"},{"product_id":"n-a-4","title":"#14\/2 Fire Alarm Jacketed, Plenum FPLP - 1000ft Reel - Red","description":"\u003cp\u003e\u003cstrong\u003eThis product may be available in one of our regional warehouses.   Call us for best shipping option! \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 14\/2FPLP is a plenum rated 14 gauge 2 conductor FPLP solid fire alarm wire used for power limited fire alarm and communications applications.  It is perfect for wiring fire alarm systems, smoke detectors, and various fire protective circuits in plenum open-air ventilation environments.  The plenum rated jacket on the 14-2 fire alarm wire is designed to support building codes that require plenum cabling.   \u003c\/p\u003e\n\u003cp\u003eThis 14-2 fire alarm wire is sun resistance, includes a ripcord and sequential footage markings, and has color coded conductors for easy identification.  It is constructed using 14 gauge solid bare copper conductors and supports 300v operations.  14-2 FPLP fire alarm wire is common for commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eOur 14-2 FPLP fire alarm wire is manufactured to Type FPLP, NEC Article 760, CUL Type CMP\/FT6, and California State Fire Marshal standards. Type FPLP power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft, from floor to floor, or in a plenum open-air circulation ceiling environments. \u003c\/p\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":51158881665345,"sku":"VER-216-142\/P\/RD","price":410.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/Capturadepantalla2026-04-07153244.png?v=1775597586"},{"product_id":"n-a-5","title":"#18\/2 Fire Alarm Jacketed, Plenum FPLP - 1000ft Reel - Red","description":"\u003cp data-start=\"172\" data-end=\"458\"\u003eThis FPLP (Fire Power-Limited Plenum) cable is designed for fire protective signaling circuits, delivering reliable performance in critical life-safety applications. It features 18 AWG solid bare copper conductors in a 4-conductor configuration, ensuring consistent signal transmission.\u003c\/p\u003e\n\u003cp data-start=\"460\" data-end=\"723\"\u003eThe cable is shielded to protect against electromagnetic (EMI) and radio frequency interference (RFI), making it ideal for environments with potential signal disruption. Rated for plenum spaces, it meets strict fire safety standards for use in air-handling areas.\u003c\/p\u003e\n\u003cp data-start=\"725\" data-end=\"822\"\u003eETL listed and RoHS compliant, this cable comes in a 1000 ft spool for large-scale installations.\u003c\/p\u003e\n\u003cp data-start=\"824\" data-end=\"849\"\u003e\u003cstrong data-start=\"824\" data-end=\"849\"\u003eApplications include:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"850\" data-end=\"978\"\u003e\n\u003cli data-section-id=\"kez4t1\" data-start=\"850\" data-end=\"880\"\u003eSmoke alarms and detectors\u003c\/li\u003e\n\u003cli data-section-id=\"1fn08el\" data-start=\"881\" data-end=\"917\"\u003ePull stations and control panels\u003c\/li\u003e\n\u003cli data-section-id=\"d6wzbk\" data-start=\"918\" data-end=\"943\"\u003eBurglar alarm systems\u003c\/li\u003e\n\u003cli data-section-id=\"j2i6kp\" data-start=\"944\" data-end=\"978\"\u003eAddressable fire alarm systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":51158881698113,"sku":"VER-216-182\/P\/RD","price":175.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/Capturadepantalla2026-04-07152852.png?v=1775597360"},{"product_id":"n-a-6","title":"#18\/4 Fire Alarm Jacketed, Plenum FPLP - 1000ft Reel - Red","description":"\u003cdiv class=\"container bg-white\"\u003e\n\u003cdiv id=\"content\" class=\"col-sm-12\" data-hook=\"\"\u003e\n\u003cdiv data-hook=\"product_show\" class=\"row\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/Product\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-12\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane active\" id=\"product-tabs-description\"\u003e\n\u003cdiv id=\"description\" class=\"padding-top\"\u003e\n\u003cp\u003eThe 18\/4FPLP is a shielded plenum rated 18 gauge 4 conductor FPLP solid fire alarm wire used for power limited fire alarm and communications applications.  It is perfect for wiring fire alarm systems, smoke detectors, and various fire protective circuits in plenum open-air ventilation environments.  The plenum rated jacket on the 18-4 fire alarm wire is designed to support building codes that require plenum cabling.  It also includes an overall shielding that will protect your signals from any outside interference that could interrupt the integrity of your fire alarm system.   \u003c\/p\u003e\n\u003cp\u003eThis 18-4 fire alarm wire includes a ripcord, drain wire, plenum jacket, sequential footage markings, and an overall foil shield.  It is constructed using 18 gauge solid bare copper conductors and supports 300v operations.  18-4 Shielded FPLP fire alarm wire is common for commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003eOur 18-4 FPLP fire alarm wire is manufactured to Type FPLP, NEC Article 760, CUL Type CMP\/FT6, and California State Fire Marshal standards. Type FPLP power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft, from floor to floor, or in a plenum open-air circulation ceiling environments.  \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":51158881730881,"sku":"VER-216-184\/P\/RD","price":330.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/Capturadepantalla2026-04-07152852.png?v=1775597360"},{"product_id":"12-2-fire-alarm-jacketed-fplp-br-m-ft-reel-red","title":"#12\/2 Fire Alarm Jacketed, Plenum FPLP - 1000ft Reel - Red","description":"\u003cp\u003eThe \u003cstrong\u003e12\/2FPLP Fire Alarm Cable\u003c\/strong\u003e is a 2-conductor, 12 AWG solid copper plenum-rated cable designed for power-limited fire alarm and communication systems. Featuring low-smoke PVC insulation and a durable red low-smoke PVC jacket, this unshielded FPLP cable is suitable for fire alarm systems, smoke detectors, monitoring and detection systems, signal and control circuits, initiating circuits, and notification circuits.\u003c\/p\u003e\n\u003cp\u003eThe cable features twisted solid bare copper conductors, an integrated ripcord for easy jacket removal, and sequential foot markings for convenient installation and cable management. It is \u003cstrong\u003eETL rated FPLP and CL2P\u003c\/strong\u003e and is supplied on a \u003cstrong\u003e1,000 ft spool\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e2 Conductors \/ 12 AWG Solid Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFPLP Plenum-Rated Fire Alarm Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnshielded Construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-Smoke PVC Insulation and Jacket\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRed Jacket\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSequential Foot Markings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated Ripcord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eETL FPLP, CL2P\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1,000 ft Spool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eComparable Products:\u003c\/strong\u003e Belden 6020UL \/ 6120UL, Honeywell 4515, Coleman 81202, and Liberty 12-2C-FPLP-RED.\u003c\/p\u003e","brand":"Structured Cable Products Inc. (SimpleBrands)","offers":[{"title":"Default Title","offer_id":52085972369729,"sku":"SCP-12\/2FPLP","price":733.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/Capturadepantalla2026-08-17123500.png?v=1786991722"},{"product_id":"14-4-fire-alarm-plenum-fplp-br-m-ft-reel-red","title":"#14\/4 Fire Alarm Jacketed, Plenum FPLP - 1000ft Reel - Red","description":"\u003cp\u003eThe \u003cstrong\u003e14\/4 FPLP Fire Alarm Cable\u003c\/strong\u003e is a 4-conductor, 14 AWG plenum-rated cable designed for power-limited fire alarm and fire protective signaling systems. Made with \u003cstrong\u003e100% solid bare copper conductors\u003c\/strong\u003e, it provides reliable performance for a variety of fire and security applications.\u003c\/p\u003e\n\u003cp\u003eIdeal for \u003cstrong\u003esmoke alarms and detectors, pull boxes, burglar alarms, and addressable fire alarm systems\u003c\/strong\u003e, this FPLP cable is suitable for installations requiring plenum-rated fire alarm wiring. It is \u003cstrong\u003eETL Listed and RoHS Compliant\u003c\/strong\u003e and comes on a \u003cstrong\u003e1,000 ft spool\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e14 AWG \/ 4 Conductor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFPLP Plenum-Rated Fire Alarm Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e100% Solid Bare Copper Conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFire Protective Signal Circuit Applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for Smoke Alarms and Detectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for Pull Boxes and Burglar Alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAddressable Fire Alarm System Applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eETL Listed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1,000 ft Spool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":52085972435265,"sku":"VER-216-144\/P\/RD","price":714.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/Capturadepantalla2026-08-17130548.png?v=1786993605"},{"product_id":"16-4-fire-alarm-jacketed-shielded-fplp-br-m-ft-reel-red","title":"#16\/4 Fire Alarm Jacketed, Plenum Shielded FPLP - 1000ft Reel - Red","description":"\u003cp\u003eThe \u003cstrong\u003e16\/4 Shielded FPLP Fire Alarm Cable (216-164\/S\/P\/RD)\u003c\/strong\u003e is a 4-conductor, 16 AWG plenum-rated cable designed for fire alarm and emergency communication systems. Its \u003cstrong\u003eshielded construction helps reduce signal interference\u003c\/strong\u003e, while solid bare copper conductors provide reliable conductivity for critical signaling applications.\u003c\/p\u003e\n\u003cp\u003eIdeal for \u003cstrong\u003efire alarm circuits, smoke detectors, pull stations, and emergency communication systems\u003c\/strong\u003e, this cable is designed for installations in plenum and air-handling spaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e16 AWG \/ 4 Conductor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFPLP Plenum-Rated Fire Alarm Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielded Construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSolid Bare Copper Conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHelps Reduce Signal Interference\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for Fire Alarm and Emergency Communication Systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for Plenum \/ Air-Handling Spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":52085972697409,"sku":"VER-216-164\/S\/P\/RD","price":422.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/Capturadepantalla2026-08-17130603.png?v=1786993604"},{"product_id":"16-4-fire-alarm-jacketed-fplp-br-m-ft-reel-red","title":"#16\/4 Fire Alarm Jacketed, Plenum FPLP - 1000ft Reel - Red","description":"\u003cp\u003eThe \u003cstrong\u003e16\/4 FPLP Fire Alarm Cable\u003c\/strong\u003e is a 4-conductor, 16 AWG plenum-rated cable designed for power-limited fire alarm and fire protective signaling circuits. Made with \u003cstrong\u003esolid bare copper conductors\u003c\/strong\u003e, it provides reliable connectivity for fire alarm and security system installations.\u003c\/p\u003e\n\u003cp\u003eIdeal for \u003cstrong\u003esmoke alarms and detectors, pull boxes, burglar alarms, and addressable fire alarm systems\u003c\/strong\u003e, this cable is \u003cstrong\u003eETL Listed and RoHS Compliant\u003c\/strong\u003e and comes on a \u003cstrong\u003e1,000 ft spool\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e16 AWG \/ 4 Conductor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFPLP Plenum-Rated Fire Alarm Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSolid Bare Copper Conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFire Protective Signal Circuit Applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eETL Listed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1,000 ft Spool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Vertical Cable","offers":[{"title":"Default Title","offer_id":52085976334657,"sku":"VER-216-164\/P\/RD","price":441.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/3440\/8257\/files\/Capturadepantalla2026-08-17130603.png?v=1786993604"}],"url":"https:\/\/cablingplus.com\/collections\/pendant-speakers-copy.oembed","provider":"CablingPlus","version":"1.0","type":"link"}